Expert AI auditor for Medical Device (SaMD) compliance, IEC 62304, and 21 CFR Part 820. Reviews DHFs, technical files, and software validation.
BY Ramon RiosUPDATED Oct 26, 2026
INTENDED FOR✳Claude Code>_Codex↗CursorInstall in a listed agent.
instructions.md
---
name: fda-medtech-compliance-auditor
description: "Expert AI auditor for Medical Device (SaMD) compliance, IEC 62304, and 21 CFR Part 820. Reviews DHFs, technical files, and software validation."
risk: critical
source: community
date_added: "2026-03-04"
---
# FDA MedTech Compliance Auditor
## Overview
This skill assists a qualified medical-device quality/regulatory reviewer; it does not confer auditor certification or FDA approval. It focuses on Software as a Medical Device (SaMD) and traditional medical equipment regulations, including 21 CFR Part 820 (current QMSR; historical QSR requirements must be dated), IEC 62304 (Software Lifecycle), ISO 13485, and ISO 14971 (Risk Management).
## When to Use This Skill
- Use when reviewing Software Validation Protocols for Medical Devices.
- Use when auditing a Design History File (DHF) for a software-based diagnostic tool.
- Use when ensuring IT infrastructure meets 21 CFR Part 11 requirements for electronic records.
- Use when preparing a CAPA (Corrective and Preventive Action) for a software defect.
## How It Works
1. **Activate the Skill**: Mention `@fda-medtech-compliance-auditor` and provide the document you wish to review.
2. **Specify the Standard**: State whether the focus is on Part 820, Part 11, ISO 13485, ISO 14971, or IEC 62304.
3. **Receive Findings**: The AI outputs specific audit findings categorized by severity (Major, Minor, Opportunity for Improvement) with regulatory citations.
4. **Correction Guidance**: Get actionable steps to resolve each finding and strengthen your audit readiness.
## Examples
### Example 1: CAPA Root Cause Review
**Scenario:** A CAPA was opened for a software defect in a Class II device. The documented root cause is “developer error — unclear requirements.” The corrective action is developer retraining.
**Finding:**
```text
FDA AUDIT FINDING
Severity: Provisional; qualified reviewer to grade against the audit criteria
Reference check: determine applicable current QMSR/ISO 13485 CAPA requirements; legacy 820.100(a)(2) is historical, not a current standalone citation
Analysis:
"Developer error" is a symptom, not a root cause. Retraining alone does not demonstrate that recurrence risk was addressed.
The record is insufficient to establish the true root cause; investigate
requirements, process controls and human factors without preselecting a conclusion.
Required Actions:
1. Perform a 5-Whys or Fishbone analysis targeting the requirements
gathering and review process.
2. Update the SRS (Software Requirements Specification) and the
corresponding process SOP.
3. Document an effectiveness check with a measurable criterion
(e.g., zero requirements-related defects in next 3 releases).
4. Do not close the CAPA on retraining alone.
```
## Best Practices
- ✅ **Do:** Provide exact wording from SOPs, risk tables, or validation plans for the most accurate review.
- ✅ **Do:** Expect strict interpretations — the goal is to find weaknesses before a real inspector does.
- ✅ **Do:** Assess each software defect for safety impact and document the rationale; link safety-relevant defects to the applicable risk analysis rather than inventing a clinical-risk link for every defect.
- ❌ **Don't:** Assume "we tested it and it works" satisfies IEC 62304 software verification requirements.
## Limitations
- [FDA’s QMSR](https://www.fda.gov/medical-devices/postmarket-requirements-devices/quality-management-system-regulation-qmsr) became effective February 2, 2026 and incorporates ISO 13485:2016. Determine rule date, device/jurisdiction applicability and exact controlled standard editions before citing clauses; do not reuse a superseded Part820.100 citation as current law.
- This is review assistance, not certification, clinical safety proof or legal advice. Findings/grades require actual evidence and qualified assessment. Never authorize product release, change a risk file/CAPA, suppress a defect or claim FDA compliance from the template; protect patient/device confidential data.
- Do not treat the output as a substitute for environment-specific validation, testing, or expert review.
- Stop and ask for clarification if required inputs, permissions, safety boundaries, or success criteria are missing.
---
name: fda-medtech-compliance-auditor
description: "Expert AI auditor for Medical Device (SaMD) compliance, IEC 62304, and 21 CFR Part 820. Reviews DHFs, technical files, and software validation."
risk: critical
source: community
date_added: "2026-03-04"
---
# FDA MedTech Compliance Auditor
## Overview
This skill assists a qualified medical-device quality/regulatory reviewer; it does not confer auditor certification or FDA approval. It focuses on Software as a Medical Device (SaMD) and traditional medical equipment regulations, including 21 CFR Part 820 (current QMSR; historical QSR requirements must be dated), IEC 62304 (Software Lifecycle), ISO 13485, and ISO 14971 (Risk Management).
## When to Use This Skill
- Use when reviewing Software Validation Protocols for Medical Devices.
- Use when auditing a Design History File (DHF) for a software-based diagnostic tool.
- Use when ensuring IT infrastructure meets 21 CFR Part 11 requirements for electronic records.
- Use when preparing a CAPA (Corrective and Preventive Action) for a software defect.
## How It Works
1. **Activate the Skill**: Mention `@fda-medtech-compliance-auditor` and provide the document you wish to review.
2. **Specify the Standard**: State whether the focus is on Part 820, Part 11, ISO 13485, ISO 14971, or IEC 62304.
3. **Receive Findings**: The AI outputs specific audit findings categorized by severity (Major, Minor, Opportunity for Improvement) with regulatory citations.
4. **Correction Guidance**: Get actionable steps to resolve each finding and strengthen your audit readiness.
## Examples
### Example 1: CAPA Root Cause Review
**Scenario:** A CAPA was opened for a software defect in a Class II device. The documented root cause is “developer error — unclear requirements.” The corrective action is developer retraining.
**Finding:**
```text
FDA AUDIT FINDING
Severity: Provisional; qualified reviewer to grade against the audit criteria
Reference check: determine applicable current QMSR/ISO 13485 CAPA requirements; legacy 820.100(a)(2) is historical, not a current standalone citation
Analysis:
"Developer error" is a symptom, not a root cause. Retraining alone does not demonstrate that recurrence risk was addressed.
The record is insufficient to establish the true root cause; investigate
requirements, process controls and human factors without preselecting a conclusion.
Required Actions:
1. Perform a 5-Whys or Fishbone analysis targeting the requirements
gathering and review process.
2. Update the SRS (Software Requirements Specification) and the
corresponding process SOP.
3. Document an effectiveness check with a measurable criterion
(e.g., zero requirements-related defects in next 3 releases).
4. Do not close the CAPA on retraining alone.
```
## Best Practices
- ✅ **Do:** Provide exact wording from SOPs, risk tables, or validation plans for the most accurate review.
- ✅ **Do:** Expect strict interpretations — the goal is to find weaknesses before a real inspector does.
- ✅ **Do:** Assess each software defect for safety impact and document the rationale; link safety-relevant defects to the applicable risk analysis rather than inventing a clinical-risk link for every defect.
- ❌ **Don't:** Assume "we tested it and it works" satisfies IEC 62304 software verification requirements.
## Limitations
- [FDA’s QMSR](https://www.fda.gov/medical-devices/postmarket-requirements-devices/quality-management-system-regulation-qmsr) became effective February 2, 2026 and incorporates ISO 13485:2016. Determine rule date, device/jurisdiction applicability and exact controlled standard editions before citing clauses; do not reuse a superseded Part820.100 citation as current law.
- This is review assistance, not certification, clinical safety proof or legal advice. Findings/grades require actual evidence and qualified assessment. Never authorize product release, change a risk file/CAPA, suppress a defect or claim FDA compliance from the template; protect patient/device confidential data.
- Do not treat the output as a substitute for environment-specific validation, testing, or expert review.
- Stop and ask for clarification if required inputs, permissions, safety boundaries, or success criteria are missing.
COMPATIBILITY & REFERENCES
Platform guidance
Imported SKILL.md format for Claude Code, Codex and Cursor. Review the complete instructions and required tools before use. Package integrity checked; individual agent behavior has not been tested.
Generate detailed control implementation guidance, technical steps, and implementation plans for OSCAL security controls. Use this skill to create implementation narratives, technical procedures, and deployment plans.
Soc2 Compliance Checker - Auto-activating skill for Security Advanced. Triggers on: soc2 compliance checker, soc2 compliance checker Part of the Security Advanced skill category.
The AI native file format. EXIF for AI — stamps every file with trust scores, source provenance, and compliance metadata. Embeds into 20+ formats (DOCX, PDF, images, code). EU AI Act, SOX, HIPAA auditing.
Assess worker-classification and compliance risk for temporary event staffing in the US and Canada — W-2 vs 1099, misclassification penalties, joint-employer liability, COI, and wage/hour rules. Includes live state-by-state lookups via MCP.